FREE Shipping

Available Mon-Fri, 8am - 5pm EST at 267-507-5660

60-DAYS Money Back Guarantee

Brand image

Cat6A Ethernet Cable Shielded CMR Riser 23AWG Solid Bare Copper 750MHz 1000ft

SKU: 4049-Big
Regular price $294.99
  • 23AWG Solid Bare Copper · 4 Shielded Pairs
  • AL-Foil FTP Shield + Drain Wire · HDPE
  • CMR/FT4 Rated · C(ETL) Listed · TIA-568-C.2
  • 750MHz · 10G Base-T · OD 0.3153 in. · NVP 69%
  • Spline Separator · Rip Cord · 1000ft Reel
Color: Blue
Save More on Bulk OrdersGet better pricing on bulk purchases!

FREE SHIPPING

FREE SHIPPING

Fast and secure shipping on all orders

60-days FREE RETURN

60-days FREE RETURN

Easy returns within 60 days

LIFETIME WARRANTY

LIFETIME WARRANTY

Backed by Lifetime Warranty

TRUSTED BY INSTALLERS

TRUSTED BY INSTALLERS

Contractors and network professionals

  • 𝐁𝐔𝐈𝐋𝐓 𝐅𝐎𝐑 𝐈𝐍𝐓𝐄𝐑𝐅𝐄𝐑𝐄𝐍𝐂𝐄 𝐙𝐎𝐍𝐄𝐒 AL-foil shield with drain wire blocks EMI from motors, power lines, and dense cable runs — essential where unshielded UTP would degrade signal.
  • 𝐒𝐎𝐋𝐈𝐃 𝐁𝐀𝐑𝐄 𝐂𝐎𝐏𝐏𝐄𝐑 𝟐𝟑𝐀𝐖𝐆 Solid bare copper conductors deliver superior conductivity and reliable 10G performance at 750MHz — across every shielded run, every time.
  • 𝐒𝐏𝐋𝐈𝐍𝐄 + 𝐒𝐇𝐈𝐄𝐋𝐃: 𝐃𝐎𝐔𝐁𝐋𝐄 𝐍𝐄𝐗𝐓 Spline separator reduces NEXT and AXT inside the cable while the AL-foil handles external EMI — two lines of crosstalk defense in one cable.
  • 𝐂𝐌𝐑 𝐑𝐀𝐓𝐄𝐃 𝐅𝐎𝐑 𝐄𝐕𝐄𝐑𝐘 𝐖𝐀𝐋𝐋 CMR/FT4-rated jacket meets fire code for permanent in-wall and riser installations — one cable for every non-plenum run in the building.
  • 𝐏𝐑𝐎 𝐈𝐍𝐒𝐓𝐀𝐋𝐋𝐀𝐓𝐈𝐎𝐍 𝐅𝐄𝐀𝐓𝐔𝐑𝐄𝐒 1000ft reel with rip cord and sequential footage markings for fast jacket removal and accurate pulls. Requires shielded RJ45 connectors and grounding.

Description

Cat6A FTP (Foiled Twisted Pair) shielded riser cable for 10G network infrastructure. An aluminum foil shield wraps all four twisted pairs with a drain wire for complete, groundable EMI protection — the key advantage over unshielded UTP in industrial floors, data centers, and locations near power equipment. Supports 10/100/1000/10G Base-T (IEEE 802.3) at up to 750MHz. Backward compatible with Cat6 and Cat5e.

23AWG solid bare copper conductors with HDPE insulation. Spline separator reduces NEXT and Alien Crosstalk (AXT) in addition to the foil shield. Rip cord for clean jacket removal. CMR/FT4-rated FR-PVC jacket for in-wall and riser installation. OD: 0.3153 in. NVP: 69%.

Note: FTP cable requires shielded RJ45 connectors and proper grounding at both termination points.

Standards: C(ETL) Listed FT4 CMR · C(ETL)US Verified ANSI/TIA-568-C.2 · RoHS Compliant.

• Conductor: 23 AWG Solid Bare Copper · Pairs: 4 FTP
• Shield: AL-Foil + Drain Wire · Insulation: HDPE
• Jacket: FR-PVC CMR/FT4 · OD: 0.3153 in. · NVP: 69%
• Performance: 750MHz · 10G Base-T · Spline Separator: Yes · Rip Cord: Yes
• Packaging: 1000ft Reel
• Colors: Blue, Black, Grey, Red, White, Yellow · Length: 1000ft

Specifications

  • Cable Type
    Cat6A
  • Bandwidth
    750 MHz
  • Conductor
    Solid Bare Copper
  • Pairs
    4 Twisted Pairs
  • Shielding
    Shielded
  • Insulation
    HDPE Insulation
  • Jacket
    Flame Retardant PVC Jacket
  • Colors
    Multicolor

Payment & Security

  • Amazon
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Venmo
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.