Fire Alarm Cable FPLR 16/4 Solid Bare Copper Conductor Shielded Riser 1000ft Red
-
16AWG Solid Bare Copper · 4 Conductors (Class A)
-
AL-Foil Shield + Drain Wire · PVC Insulation
-
C(UL) Listed FPLR · UL 1424 · UL 1666
-
OD 0.220 in. · 51 lbs/1000ft · Temp 75°C
-
FR-PVC Jacket · Rip Cord · NEC Article 760
Fire Alarm Cable FPLR 16/4 Solid Bare Copper Conductor Shielded Riser 1000ft Red - Shielded is backordered and will ship as soon as it is back in stock.
Save More on Bulk Orders
Fire Alarm Cable FPLR 16/4 Solid Bare Copper Conductor Shielded Riser 1000ft Red - Shielded is backordered and will ship as soon as it is back in stock.
-
𝐅𝐏𝐋𝐑 𝐑𝐀𝐓𝐄𝐃 𝐅𝐎𝐑 𝐑𝐈𝐒𝐄𝐑 𝐑𝐔𝐍𝐒 FPLR rating meets NEC Article 760 for vertical riser shafts between floors — and also substitutes for FPL in any non-plenum location in the building.
-
𝐂𝐋𝐀𝐒𝐒 𝐀 𝐒𝐔𝐏𝐄𝐑𝐕𝐈𝐒𝐎𝐑𝐘 𝐂𝐈𝐑𝐂𝐔𝐈𝐓 4-conductor loop keeps the fire alarm system operating and pinpoints faults even when one segment is broken or shorted — required for Class A wiring.
-
𝐀𝐋-𝐅𝐎𝐈𝐋 𝐁𝐋𝐎𝐂𝐊𝐒 𝐄𝐌𝐈 𝐀𝐍𝐃 𝐑𝐅𝐈 AL-foil shield and drain wire block EMI from motors, HVAC, and electrical panels — keeping alarm signals clean in large commercial buildings.
-
𝐋𝐎𝐍𝐆𝐄𝐑 𝐑𝐔𝐍𝐒 𝐇𝐄𝐀𝐕𝐈𝐄𝐑 𝐋𝐎𝐀𝐃𝐒 16AWG lower resistance supports longer NAC runs and more devices per circuit — choose when 18AWG limits circuit distance or device count.
-
𝐈𝐍𝐒𝐓𝐀𝐋𝐋𝐄𝐑 𝐑𝐄𝐀𝐃𝐘 𝐑𝐄𝐄𝐋 Red jacket for instant fire alarm identification. Rip cord for fast jacket removal. Sequential footage markings. 1000ft reel for large installations.
Description
Description
FPLR-rated 4-conductor shielded fire alarm cable for vertical riser runs in shafts, stairwells, and between floors in commercial, residential, and industrial fire alarm systems. FPLR is the riser rating under NEC Article 760 — required for vertical runs where cable must resist fire propagation between floors. FPLR can substitute for FPL anywhere in the building.
4-conductor construction (Black/Red/Yellow/Blue) supports Class A supervisory circuits — a closed loop configuration that allows the fire alarm system to continue operating and pinpoint the fault even if one segment of the cable is broken or shorted. 16AWG offers lower resistance than 18AWG — supporting longer NAC runs and higher device loads without excessive voltage drop. Aluminum foil shield and drain wire block EMI from motors, HVAC, lighting, and electrical equipment. PVC insulation, flame-retardant PVC jacket, rip cord. OD: 0.220 in. Weight: 51 lbs per 1000ft.
Standards: C(UL) Listed FPLR · RoHS Compliant.
• Conductor: Solid Bare Copper · AWG: 16 · Conductors: 4 (Black/Red/Yellow/Blue)
• Shield: AL-Foil + Drain Wire (Stranded TC)
• Insulation: PVC · Jacket: FR-PVC FPLR · Rip Cord: Yes
• OD: 0.220 in. (5.60 mm) · Weight: 51 lbs · Temp: 75°C
• Color: Red · Length: 1000ft · Packaging: 1000ft Reel
Specifications
Specifications
-
Cable Type
-
Conductor
-
Pairs
-
Shielding
-
Insulation
-
Jacket
-
Colors