Shielded Fire Alarm Cable 14AWG 4 Solid Conductors Bare Copper FPLR Riser 1000ft Red
-
14AWG Solid Bare Copper · 4 Conductors (Class A)
-
AL-Foil Shield + Drain Wire · PVC Insulation
-
C(UL) Listed FPLR · UL 1424 · UL 1666
-
14AWG Max Load · Lowest Resistance · Temp 75°C
-
FR-PVC Jacket · Rip Cord · NEC Article 760
Shielded Fire Alarm Cable 14AWG 4 Solid Conductors Bare Copper FPLR Riser 1000ft Red
-
𝐅𝐏𝐋𝐑 𝐑𝐀𝐓𝐄𝐃 𝐅𝐎𝐑 𝐑𝐈𝐒𝐄𝐑 𝐑𝐔𝐍𝐒 FPLR rating meets NEC Article 760 for vertical riser shafts between floors — and also substitutes for FPL in any non-plenum location in the building.
-
𝐂𝐋𝐀𝐒𝐒 𝐀 𝐒𝐔𝐏𝐄𝐑𝐕𝐈𝐒𝐎𝐑𝐘 𝐂𝐈𝐑𝐂𝐔𝐈𝐓 4-conductor loop keeps the fire alarm system operating and pinpoints faults even when one segment is broken or shorted — required for Class A wiring.
-
𝐀𝐋-𝐅𝐎𝐈𝐋 𝐁𝐋𝐎𝐂𝐊𝐒 𝐄𝐌𝐈 𝐀𝐍𝐃 𝐑𝐅𝐈 AL-foil shield and drain wire block EMI from motors, HVAC, and electrical panels — keeping alarm signals clean in large commercial buildings.
-
𝐌𝐀𝐗 𝐋𝐎𝐀𝐃 𝐌𝐀𝐗 𝐃𝐈𝐒𝐓𝐀𝐍𝐂𝐄 14AWG has the lowest resistance in the fire alarm range — for the longest NAC runs and device counts where 16AWG or 18AWG produce voltage drop.
-
𝐈𝐍𝐒𝐓𝐀𝐋𝐋𝐄𝐑 𝐑𝐄𝐀𝐃𝐘 𝐑𝐄𝐄𝐋 Red jacket for instant fire alarm identification. Rip cord for fast jacket removal. Sequential footage markings. 1000ft reel for large installations.
Description
Description
FPLR-rated 4-conductor shielded fire alarm cable for vertical riser runs between floors. FPLR is the riser rating under NEC Article 760, required for circuits running vertically through more than 1 floor. Substitutes for FPL; FPLP substitutes for FPLR.
4-conductor construction (Black/Red/Yellow/Blue) provides the two wire pairs a Class A supervisory circuit needs to keep operating and pinpoint a fault even if one segment breaks or shorts. Note: NFPA 72 12.3 requires the outgoing and return legs of a true Class A circuit to be routed separately; confirm design and AHJ requirements first. 14AWG is the heaviest fire alarm gauge; AL-foil shield with drain wire blocks EMI from motors and panels.
Standards: C(UL) Listed FPLR · UL 1424 · UL 1666 · RoHS Compliant
Technical Specifications:
• Conductor: Solid Bare Copper · AWG: 14 · Conductors: 4 (Black/Red/Yellow/Blue)
• Shield: AL-Foil + Drain Wire (Stranded TC) · Insulation: PVC
• Jacket: FR-PVC FPLR · Rip Cord: Yes · Color: Red
• Rated Temp: 75°C
• Packaging: 1000ft Reel
Typical Applications:
• Vertical riser runs in shafts and stairwells between floors
• Class A supervisory notification and initiating circuits
• Addressable fire alarm and detection systems
• Runs near motors and electrical panels requiring EMI shielding
• Combined fire alarm and security/burglar alarm wiring