Shielded Fire Alarm Cable 14AWG 4 Solid Conductors Bare Copper FPLR Riser 1000ft Red

SKU: 4094-Big
Sale price $830.99 Regular price $1,246.49
33% off
  • 14AWG Solid Bare Copper · 4 Conductors (Class A)
  • AL-Foil Shield + Drain Wire · PVC Insulation
  • C(UL) Listed FPLR · UL 1424 · UL 1666
  • 14AWG Max Load · Lowest Resistance · Temp 75°C
  • FR-PVC Jacket · Rip Cord · NEC Article 760
Type
Save More on Bulk OrdersGet better pricing on bulk purchases!

FREE SHIPPING

FREE SHIPPING

Fast and secure shipping on all US orders

60-days FREE RETURN

60-days FREE RETURN

Easy returns within 60 days

LIFETIME WARRANTY

LIFETIME WARRANTY

Backed by Lifetime Warranty

TRUSTED BY INSTALLERS

TRUSTED BY INSTALLERS

Contractors and network professionals

Shielded Fire Alarm Cable 14AWG 4 Solid Conductors Bare Copper FPLR Riser 1000ft Red

Shielded Fire Alarm Cable 14AWG 4 Solid Conductors Bare Copper FPLR Riser 1000ft Red

Type: Shielded
$1,246.49 $830.99
  • 𝐅𝐏𝐋𝐑 𝐑𝐀𝐓𝐄𝐃 𝐅𝐎𝐑 𝐑𝐈𝐒𝐄𝐑 𝐑𝐔𝐍𝐒 FPLR rating meets NEC Article 760 for vertical riser shafts between floors — and also substitutes for FPL in any non-plenum location in the building.
  • 𝐂𝐋𝐀𝐒𝐒 𝐀 𝐒𝐔𝐏𝐄𝐑𝐕𝐈𝐒𝐎𝐑𝐘 𝐂𝐈𝐑𝐂𝐔𝐈𝐓 4-conductor loop keeps the fire alarm system operating and pinpoints faults even when one segment is broken or shorted — required for Class A wiring.
  • 𝐀𝐋-𝐅𝐎𝐈𝐋 𝐁𝐋𝐎𝐂𝐊𝐒 𝐄𝐌𝐈 𝐀𝐍𝐃 𝐑𝐅𝐈 AL-foil shield and drain wire block EMI from motors, HVAC, and electrical panels — keeping alarm signals clean in large commercial buildings.
  • 𝐌𝐀𝐗 𝐋𝐎𝐀𝐃 𝐌𝐀𝐗 𝐃𝐈𝐒𝐓𝐀𝐍𝐂𝐄 14AWG has the lowest resistance in the fire alarm range — for the longest NAC runs and device counts where 16AWG or 18AWG produce voltage drop.
  • 𝐈𝐍𝐒𝐓𝐀𝐋𝐋𝐄𝐑 𝐑𝐄𝐀𝐃𝐘 𝐑𝐄𝐄𝐋 Red jacket for instant fire alarm identification. Rip cord for fast jacket removal. Sequential footage markings. 1000ft reel for large installations.

Description

FPLR-rated 4-conductor shielded fire alarm cable for vertical riser runs between floors. FPLR is the riser rating under NEC Article 760, required for circuits running vertically through more than 1 floor. Substitutes for FPL; FPLP substitutes for FPLR.

4-conductor construction (Black/Red/Yellow/Blue) provides the two wire pairs a Class A supervisory circuit needs to keep operating and pinpoint a fault even if one segment breaks or shorts. Note: NFPA 72 12.3 requires the outgoing and return legs of a true Class A circuit to be routed separately; confirm design and AHJ requirements first. 14AWG is the heaviest fire alarm gauge; AL-foil shield with drain wire blocks EMI from motors and panels.

Standards: C(UL) Listed FPLR · UL 1424 · UL 1666 · RoHS Compliant

Technical Specifications:
• Conductor: Solid Bare Copper · AWG: 14 · Conductors: 4 (Black/Red/Yellow/Blue)
• Shield: AL-Foil + Drain Wire (Stranded TC) · Insulation: PVC
• Jacket: FR-PVC FPLR · Rip Cord: Yes · Color: Red
• Rated Temp: 75°C
• Packaging: 1000ft Reel

Typical Applications:
• Vertical riser runs in shafts and stairwells between floors
• Class A supervisory notification and initiating circuits
• Addressable fire alarm and detection systems
• Runs near motors and electrical panels requiring EMI shielding
• Combined fire alarm and security/burglar alarm wiring

Specifications

  • Colors
    Red

Payment & Security

  • Amazon
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Venmo
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.