Fire Alarm Cable 18AWG 2 Solid Conductors Bare Copper FPLR Riser 1000ft Red
-
18AWG Solid Bare Copper · 2 Conductors Black/Red
-
PVC Insulation · FR-PVC Jacket · Rip Cord
-
C(UL) Listed FPLR · UL 1424 · UL 1666
-
OD 0.157 in. · 21 lbs/1000ft · Temp 75°C
-
Unshielded · Red Jacket · NEC Article 760
Fire Alarm Cable 18AWG 2 Solid Conductors Bare Copper FPLR Riser 1000ft Red
-
𝐅𝐏𝐋𝐑 𝐑𝐀𝐓𝐄𝐃 𝐅𝐎𝐑 𝐑𝐈𝐒𝐄𝐑 𝐑𝐔𝐍𝐒 FPLR rating meets NEC Article 760 for vertical riser shafts between floors — and also substitutes for FPL in any non-plenum location in the building.
-
𝐖𝐈𝐑𝐄𝐒 𝐘𝐎𝐔𝐑 𝐅𝐈𝐑𝐄 𝐀𝐋𝐀𝐑𝐌 𝐒𝐘𝐒𝐓𝐄𝐌 Connects smoke detectors, heat detectors, alarm panels, horns, strobes, modules, and sensors in Class B initiating and notification circuits.
-
𝐒𝐎𝐋𝐈𝐃 𝐁𝐀𝐑𝐄 𝐂𝐎𝐏𝐏𝐄𝐑 𝟏𝟖𝐀𝐖𝐆 Solid bare copper delivers stable signal integrity and long-term electrical performance for fire protection circuits across the full 1000ft reel.
-
𝐔𝐍𝐒𝐇𝐈𝐄𝐋𝐃𝐄𝐃 𝐒𝐓𝐀𝐍𝐃𝐀𝐑𝐃 𝐃𝐄𝐒𝐈𝐆𝐍 Unshielded construction is the code-compliant standard for most fire alarm circuits — lightweight, flexible, and fast to route, pull, and terminate.
-
𝐈𝐍𝐒𝐓𝐀𝐋𝐋𝐄𝐑 𝐑𝐄𝐀𝐃𝐘 𝐑𝐄𝐄𝐋 Red jacket for instant fire alarm identification. Rip cord for fast jacket removal. Sequential footage markings. 1000ft reel for large installations.
Description
Description
FPLR-rated fire alarm cable for vertical riser runs in shafts, stairwells, and between floors. FPLR is the riser rating under NEC Article 760 — required wherever fire alarm circuits run vertically through more than one floor. FPLR substitutes for FPL; FPLP substitutes for FPLR.
Unshielded construction is the code-compliant standard for most fire alarm circuits — lightweight, flexible, and fast to route, pull, and terminate. 18AWG is the lightest gauge in this range, ideal for shorter runs where conduit fill and flexibility matter.
Standards: C(UL) Listed FPLR · UL 1424 · UL 1666 · RoHS Compliant
Technical Specifications:
• Conductor: Solid Bare Copper · AWG: 18 · Conductors: 2 (Black/Red)
• Insulation: PVC · Jacket: FR-PVC FPLR · Rip Cord: Yes
• Shielding: None · Color: Red
• OD: 0.157 in. · Weight: 21 lbs · Rated Temp: 75°C
• Packaging: 1000ft Reel
Typical Applications:
• Vertical riser runs in shafts and stairwells between floors
• Class B initiating circuits — smoke and heat detectors, modules, sensors
• Class B notification appliance circuits (NAC) — horns, strobes, sirens
• Shorter riser runs where flexibility eases installation
• Combined fire alarm and security/burglar alarm system wiring