Fire Alarm Cable 18AWG 4 Solid Conductors Bare Copper FPLR Riser 1000ft Red
-
18AWG Solid Bare Copper · 4 Conductors (Class A)
-
PVC Insulation · FR-PVC Jacket · Rip Cord
-
C(UL) Listed FPLR · UL 1424 · UL 1666
-
OD 0.183 in. · 35 lbs/1000ft · Temp 75°C
-
Unshielded · Red Jacket · NEC Article 760
Fire Alarm Cable 18AWG 4 Solid Conductors Bare Copper FPLR Riser 1000ft Red
-
𝐅𝐏𝐋𝐑 𝐑𝐀𝐓𝐄𝐃 𝐅𝐎𝐑 𝐑𝐈𝐒𝐄𝐑 𝐑𝐔𝐍𝐒 FPLR rating meets NEC Article 760 for vertical riser shafts between floors — and also substitutes for FPL in any non-plenum location in the building.
-
𝐂𝐋𝐀𝐒𝐒 𝐀 𝐒𝐔𝐏𝐄𝐑𝐕𝐈𝐒𝐎𝐑𝐘 𝐂𝐈𝐑𝐂𝐔𝐈𝐓 4-conductor loop keeps the fire alarm system operating and pinpoints faults even when one segment is broken or shorted — required for Class A wiring.
-
𝐒𝐎𝐋𝐈𝐃 𝐁𝐀𝐑𝐄 𝐂𝐎𝐏𝐏𝐄𝐑 𝟏𝟖𝐀𝐖𝐆 Solid bare copper delivers stable signal integrity and long-term electrical performance for fire protection circuits across the full 1000ft reel.
-
𝐖𝐈𝐑𝐄𝐒 𝐘𝐎𝐔𝐑 𝐅𝐈𝐑𝐄 𝐀𝐋𝐀𝐑𝐌 𝐒𝐘𝐒𝐓𝐄𝐌 Connects smoke detectors, heat detectors, alarm panels, horns, strobes, and modules in Class A initiating, notification, and supervisory circuits.
-
𝐈𝐍𝐒𝐓𝐀𝐋𝐋𝐄𝐑 𝐑𝐄𝐀𝐃𝐘 𝐑𝐄𝐄𝐋 Red jacket for instant fire alarm identification. Rip cord for fast jacket removal. Sequential footage markings. 1000ft reel for large installations.
Description
Description
FPLR-rated 4-conductor fire alarm cable for riser runs between floors. FPLR is the riser rating under NEC Article 760, required for circuits running through more than 1 floor. Substitutes for FPL; FPLP substitutes for FPLR.
4-conductor construction (Black/Red/Yellow/Blue) provides the two wire pairs a Class A supervisory circuit needs to keep operating and pinpoint a fault if a segment breaks or shorts. Note: NFPA 72 12.3 requires outgoing and return legs of a true Class A circuit routed separately; confirm design and AHJ requirements first. 18AWG unshielded construction is the lightest, most flexible option in this range — easy to route and terminate in shorter riser runs.
Standards: C(UL) Listed FPLR · UL 1424 · UL 1666 · RoHS Compliant
Technical Specifications:
• Conductor: Solid Bare Copper · AWG: 18 · Conductors: 4 (Black/Red/Yellow/Blue)
• Insulation: PVC · Jacket: FR-PVC FPLR · Rip Cord: Yes
• Shielding: None · Color: Red
• OD: 0.183 in. · Weight: 35 lbs · Rated Temp: 75°C
• Packaging: 1000ft Reel
Typical Applications:
• Vertical riser runs in shafts and stairwells between floors
• Class A initiating, notification, and supervisory circuits
• Addressable fire alarm and detection systems
• Shorter riser runs where flexibility eases installation
• Combined fire alarm and security/burglar alarm system wiring